WFSA technical guides · Reinforcing

Reinforcing Steel Guide South Africa

Understand mesh, Y-bar, specifications and material calculations.

Concrete reinforcement supports tensile resistance and crack control where the design requires it. This guide connects practical product information to the reinforcing mesh, Y-bar and related materials actually listed by Wholesale Fencing SA.

For builders, contractors, hardware stores, developers, farmers, DIY customers, estimators and procurement teams: compare the listed ranges, read product names, calculate theoretical mass and plan material quantities.

Mesh sheet calculatorY-bar weight calculator

WFSA supply range

Reinforcing mesh, Y-bar and Specimesh

Reinforcing mesh
REF 100 · 156 · 193 · 200 · 245 · 308 · 311 · 341 · 395 · 500 · 617 · 888. Confirm specified reference and required certification.
Y-bar diameters
5.6 · 8 · 10 · 12 · 16 · 20 · 25 · 32 mm
Y-bar lengths
6 · 12 · 13 m
Specimesh sheets
2.4 × 1.2 m; 3.15 · 4.00 · 5.00 mm wire; raw steel or galvanised
Specimesh openings
50 × 25 · 50 × 50 · 100 × 20 · 100 × 25 · 100 × 50 · 100 × 100 mm

Separate product families, not interchangeable specifications. Confirm the exact reference, opening, wire, length and finish combination.

Exact combinations and stock references

68 specifications. Open a product family below.

Economy steel reinforcing mesh (7)
Specification / configurationWFSA reference
Welded steel reinforcing mesh — REF 078; 0.78 kg/m² nominal mass; economy range.REF078S
Welded steel reinforcing mesh — REF 193; <4.8 mm wire diameter; economy range.REF193SBM
Welded steel reinforcing mesh — REF 193; 5.0 mm wire diameter; SABS range designation; confirm required certification.REF193SECO
Welded steel reinforcing mesh — REF 245; 6.0 mm wire diameter; economy range.REF245SECO
Welded steel reinforcing mesh — REF 395; 7.0 mm wire diameter; economy range.REF395SECO
Welded steel reinforcing mesh — REF 617; 9.5 mm wire diameter; economy range.REF617SECO
Welded steel reinforcing mesh — REF 888; 11 mm wire diameter; economy range.REF888SECO
Steel reinforcing mesh — SABS range (12)
Specification / configurationWFSA reference
Welded steel reinforcing mesh — REF 100; 4.0 mm wire diameter; SABS range designation; confirm required certification.REF100S
Welded steel reinforcing mesh — REF 156; 3.55 mm wire diameter; SABS range designation; confirm required certification.REF156S
Welded steel reinforcing mesh — REF 193; 5.6 mm wire diameter; SABS range designation; confirm required certification.REF193S
Welded steel reinforcing mesh — REF 200; 4.0 mm wire diameter; SABS range designation; confirm required certification.REF200S
Welded steel reinforcing mesh — REF 245; 6.3 mm wire diameter; SABS range designation; confirm required certification.REF245S
Welded steel reinforcing mesh — REF 308; 6.9 mm wire diameter; SABS range designation; confirm required certification.REF308S
Welded steel reinforcing mesh — REF 311; 7.1 mm wire diameter; SABS range designation; confirm required certification.REF311S
Welded steel reinforcing mesh — REF 341; 6.3 and 5.6 mm wire diameters; confirm direction; SABS range designation; confirm required certification.REF341S
Welded steel reinforcing mesh — REF 395; 8.0 mm wire diameter; SABS range designation; confirm required certification.REF395S
Welded steel reinforcing mesh — REF 500; 9.0 mm wire diameter; SABS range designation; confirm required certification.REF500S
Welded steel reinforcing mesh — REF 617; 10 mm wire diameter; SABS range designation; confirm required certification.REF617S
Welded steel reinforcing mesh — REF 888; 12 mm wire diameter; SABS range designation; confirm required certification.REF888S
Specimesh sheets (25)
Specification / configurationWFSA reference
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 50 × 25 mm mesh opening; 3.15 mm wire diameter; raw steel.SP24125025315B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 50 × 25 mm mesh opening; 4.00 mm wire diameter; raw steel.SP2412502540B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 50 × 25 mm mesh opening; 5.00 mm wire diameter; raw steel.SP2412502550B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 50 × 50 mm mesh opening; 3.15 mm wire diameter; raw steel.SP24125050315B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 50 × 50 mm mesh opening; 4.00 mm wire diameter; raw steel.SP2412505040B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 50 × 50 mm mesh opening; 5.00 mm wire diameter; raw steel.SP2412505050B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 50 mm mesh opening; 3.15 mm wire diameter; raw steel.SP24125010315B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 50 mm mesh opening; 4.00 mm wire diameter; raw steel.SP2412501040B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 50 mm mesh opening; 5.00 mm wire diameter; raw steel.SP2412501050B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 100 mm mesh opening; 3.15 mm wire diameter; raw steel.SP24121010315B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 100 mm mesh opening; 4.00 mm wire diameter; raw steel.SP2412101040B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 100 mm mesh opening; 5.00 mm wire diameter; raw steel.SP2412101050B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 20 mm mesh opening; 3.15 mm wire diameter; raw steel.SP24121020315B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 20 mm mesh opening; 4.00 mm wire diameter; raw steel.SP2412102040B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 25 mm mesh opening; 3.15 mm wire diameter; raw steel.SP24121025315B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 25 mm mesh opening; 4.00 mm wire diameter; raw steel.SP2412102540B
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 50 × 50 mm mesh opening; 3.15 mm wire diameter; galvanized.SP24125050315G
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 50 × 50 mm mesh opening; 4.00 mm wire diameter; galvanized.SP2412505040G
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 50 × 50 mm mesh opening; 5.00 mm wire diameter; galvanized.SP2412505050G
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 50 mm mesh opening; 3.15 mm wire diameter; galvanized.SP24125010315G
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 50 mm mesh opening; 4.00 mm wire diameter; galvanized.SP2412501040G
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 50 mm mesh opening; 5.00 mm wire diameter; galvanized.SP2412501050G
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 100 mm mesh opening; 3.15 mm wire diameter; galvanized.SP24121010315G
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 100 mm mesh opening; 4.00 mm wire diameter; galvanized.SP2412101040G
Welded steel Specimesh sheet — 2.4 × 1.2 m sheet size; 100 × 100 mm mesh opening; 5.00 mm wire diameter; galvanized.SP2412101050G
Deformed reinforcing steel bars (Y-bars) (24)
Specification / configurationWFSA reference
Deformed steel reinforcing bar (Y-bar) — 5.6 mm nominal diameter; 6 m length.YBAR6MM
Deformed steel reinforcing bar (Y-bar) — 8 mm nominal diameter; 6 m length.YBAR8MM
Deformed steel reinforcing bar (Y-bar) — 10 mm nominal diameter; 6 m length.YBAR10MM
Deformed steel reinforcing bar (Y-bar) — 12 mm nominal diameter; 6 m length.YBAR12MM
Deformed steel reinforcing bar (Y-bar) — 16 mm nominal diameter; 6 m length.YBAR16MM
Deformed steel reinforcing bar (Y-bar) — 20 mm nominal diameter; 6 m length.YBAR20MM
Deformed steel reinforcing bar (Y-bar) — 25 mm nominal diameter; 6 m length.YBAR25MM
Deformed steel reinforcing bar (Y-bar) — 32 mm nominal diameter; 6 m length.YBAR32MM
Deformed steel reinforcing bar (Y-bar) — 5.6 mm nominal diameter; 12 m length.YBAR6MM12
Deformed steel reinforcing bar (Y-bar) — 8 mm nominal diameter; 12 m length.YBAR8MM12
Deformed steel reinforcing bar (Y-bar) — 10 mm nominal diameter; 12 m length.YBAR10MM12
Deformed steel reinforcing bar (Y-bar) — 12 mm nominal diameter; 12 m length.YBAR12MM12
Deformed steel reinforcing bar (Y-bar) — 16 mm nominal diameter; 12 m length.YBAR16MM12
Deformed steel reinforcing bar (Y-bar) — 20 mm nominal diameter; 12 m length.YBAR20MM12
Deformed steel reinforcing bar (Y-bar) — 25 mm nominal diameter; 12 m length.YBAR25MM12
Deformed steel reinforcing bar (Y-bar) — 32 mm nominal diameter; 12 m length.YBAR32MM12
Deformed steel reinforcing bar (Y-bar) — 5.6 mm nominal diameter; 13 m length.YBAR6MM13
Deformed steel reinforcing bar (Y-bar) — 8 mm nominal diameter; 13 m length.YBAR8MM13
Deformed steel reinforcing bar (Y-bar) — 10 mm nominal diameter; 13 m length.YBAR10MM13
Deformed steel reinforcing bar (Y-bar) — 12 mm nominal diameter; 13 m length.YBAR12MM13
Deformed steel reinforcing bar (Y-bar) — 16 mm nominal diameter; 13 m length.YBAR16MM13
Deformed steel reinforcing bar (Y-bar) — 20 mm nominal diameter; 13 m length.YBAR20MM13
Deformed steel reinforcing bar (Y-bar) — 25 mm nominal diameter; 13 m length.YBAR25MM13
Deformed steel reinforcing bar (Y-bar) — 32 mm nominal diameter; 13 m length.YBAR32MM13

Request a quotation for these specifications →

Reinforcing specification and traceability details

The full WFSA range includes Econo mesh, specified reinforcing mesh, Y-bar and Specimesh. Keep the mesh reference and range together: an Econo item carrying a familiar REF name must be checked by its actual wire size and pitch.

Nominal reinforcing-bar mass reference

Nominal bar diameter (mm)Reference kg/m6 m nominal mass (kg)12 m nominal mass (kg)13 m nominal mass (kg)
60.2221.3322.6642.886
80.3952.374.745.135
100.6173.7027.4048.021
120.8885.32810.65611.544
161.589.4818.9620.54
202.4714.8229.6432.11
253.8523.146.250.05
326.3137.8675.7282.03

This is a mill reference table. WFSA’s listed 5.6 mm Y-bar is a separate ordering size; it must not be renamed Y6 or assigned the Y6 mass. A diameter-based calculator may differ slightly because it uses ideal geometry instead of the rounded reference mass.

What must accompany specified reinforcement?

Record diameter or REF reference, grade, applicable standard, length or sheet size, wire spacing in both directions, quantity and any cut-and-bend schedule. Retain bundle or batch identification when material is split. Where required, obtain chemical and mechanical test documentation for the supplied batch.

For REF mesh, retain all supplied reference sizes and the stated 2.4 × 6 m sheet format. For Specimesh, retain the separate 2.4 × 1.2 m sheet format and its actual aperture, wire diameter and finish. The two sheet families serve different specifications.

What Is Concrete Reinforcement?

Concrete reinforcement is steel or another approved reinforcing material placed within concrete to help the finished element resist forces that plain concrete does not handle efficiently on its own.

Concrete performs strongly under compression but has comparatively limited tensile strength. An approved design may require reinforcement for tensile stresses, bending, shear and crack control. Steel type, quantity and position are part of that design; adding an arbitrary mesh sheet does not make a concrete element structurally adequate.

Why Is Steel Used to Reinforce Concrete?

Steel carries tensile forces while concrete carries compression and surrounds and protects the reinforcement. Bond and anchorage allow the materials to work together.

Performance depends on the specified reinforcement type, steel area, position, cover, laps and anchorage, as well as concrete strength, placing, compaction and curing. Keep to the approved drawings throughout construction. A quantity estimate or product name cannot establish the required reinforcement.

What Is Reinforcing Mesh?

Reinforcing mesh, also called welded reinforcing fabric, consists of steel wires arranged in a regular grid and welded at their intersections. Sheets provide distributed reinforcement within concrete.

Mesh is used in specified floor slabs, concrete paving, driveways, paths, precast work, selected foundations and walls. Its role and position vary by design. Reinforcing fabric is different from general-purpose fencing mesh: a fencing product should not replace a specified reinforcing product.

What Does REF Mean in Reinforcing Mesh?

REF designations such as REF100 and REF193 identify reinforcing fabric specifications. The numbers are not wire diameters.

Use the reinforcement schedule and product specification to establish the exact wires in each direction, spacing, steel area, sheet dimensions and compliance requirements. Standard REF100 uses 4.0 mm wire. The lighter economy sheet is REF078, with a nominal mass of 0.78 kg/m². These are distinct fabric designations.

What Is REF100 Reinforcing Mesh?

WFSA supplies REF078 ECO. This REF078 economy sheet has a nominal mass of 0.78 kg/m² and a 2.4 m × 6 m sheet size, giving a nominal sheet mass of 11.232 kg.

REF100 with a 4.0 mm SABS label is also part of the WFSA supply range; contact WFSA for a quotation and required documentation.

What Is REF193 Reinforcing Mesh?

WFSA lists two REF193 variants: Econo, <4.8 mm, and SABS-labelled, listed as 5.6 mm. Both are supplied in 2.4 m × 6 m sheets.

Their shop-listed masses are 18 kg and 27.792 kg respectively. The standard REF193 example in WFSA’s selection sheet gives 5.6 mm wires at 200 × 200 mm and nominal 1.93 kg/m².

What Is ECO Reinforcing Mesh?

ECO or Econo identifies WFSA’s economy mesh range. Inspect the actual wire diameter, spacing, sheet dimensions and project requirements rather than treating the reference name as proof of equivalent reinforcement.

The Econo range uses smaller wire diameters than the standard examples in the selection sheet. Do not substitute Econo mesh for an engineer-specified compliant fabric without the responsible designer’s approval. A lower price or matching REF number is not an approval for substitution.

What Is the Difference Between ECO and SABS/SANS Reinforcing Mesh?

A reference name, a trade label and documented compliance are different things. The WFSA shop labels one REF193 product “SABS / 5.6MM”; this guide reports that label without independently certifying the product.

Where a project requires a particular standard, steel grade, yield strength or certification, include it in your enquiry and confirm the required documentation before ordering. The selection PDF cites SANS 1024:2012 as its technical basis; confirm the edition and requirements applicable to your project with the responsible engineer.

How Do You Read a Reinforcing Mesh Specification?

DetailWhat to check
DesignationREF reference and range, for example REF193 Econo
Wire diameterActual nominal wires in each direction, with permitted tolerances
Wire spacingBoth directions; do not derive spacing from sheet width
Sheet width and lengthWFSA confirms 2.4 m × 6 m for the WFSA REF supply range
Sheet massWhether nominal, theoretical, measured or shop-listed
ComplianceRequired standard, grade and traceable documentation

Read the full schedule, not just a quotation shorthand. A mesh designation must be reconciled with the designer’s specified steel area, spacing, arrangement and material requirements.

Reinforcing Mesh Wire Diameter

REF193 Econo is specified as <4.8 mm wire, while the SABS-labelled REF193 sheet uses 5.6 mm wire. REF078 economy mesh is identified by its nominal mass of 0.78 kg/m².

Diameter affects steel cross-sectional area quadratically. It must be considered together with wire spacing and steel properties; changing one can change the reinforcement provided. Do not infer yield strength, grade or certified steel area from diameter alone.

What Size Is a Reinforcing Mesh Sheet?

WFSA REF reinforcing mesh sheets are confirmed by WFSA as 2.4 m wide × 6 m long. Each has a gross sheet area of 14.4 m².

Gross area is not effective installed coverage after laps and cutting. The shop’s repeated 600 × 7.05 × 7.05 cm dimensions are not used here as mesh sheet dimensions. Plan transport, unloading, lifting and access for the actual full sheet.

How Much Does Reinforcing Mesh Weigh?

Listed rangeWire diameterSheet sizeShop-listed massProduct
REF078 Econo—2.4 × 6 m11.232 kgView product ↗
REF193 Econo<4.8 mm2.4 × 6 m18 kgView product ↗
REF193 SABS-labelled5.6 mm2.4 × 6 m27.792 kgView product ↗

These masses are displayed in the shop’s Additional information panel; they are not represented as a guaranteed scale weight or independently measured value. The 27.792 kg listing equals 14.4 m² × the selection sheet’s standard REF193 nominal 1.93 kg/m².

What Is the Difference Between REF078 and REF193?

DetailREF078 EconoREF193 EconoREF193 SABS-labelled
Wire diameter—<4.8 mm5.6 mm
Confirmed sheet size2.4 × 6 m2.4 × 6 m2.4 × 6 m
Shop-listed mass11.232 kg18 kg27.792 kg
Spacing evidence200 × 200 mm standard REF193 example in WFSA selection sheet
Compliance evidenceNot established by ECO labelNot established by ECO labelSABS shop label; documentation must be confirmed

The variants provide different reinforcement specifications. It is misleading to reduce the decision to “REF193 is stronger”: the required fabric depends on the design, steel content, grade, spacing, position, anchorage and concrete element.

What Is Y-Bar Reinforcing Steel?

Y-bar is a deformed steel reinforcing bar used in reinforced concrete. It is commonly called reinforcing bar, rebar or deformed reinforcing bar in South Africa.

Individual bars are placed and tied to the approved reinforcement drawing, often in grids or cages. Select the bar diameter, length, steel grade and yield strength specified in the approved reinforcement schedule.

Why Does Y-Bar Have Ribs?

Ribs improve mechanical interaction and bond between reinforcing steel and surrounding concrete compared with a smooth plain bar.

Good bond still relies on the correct concrete, bar condition, cover, development/anchorage, placing and compaction. Ribbed appearance alone does not prove grade or certification. Do not grind off ribs, apply an unapproved coating, weld or modify reinforcement contrary to the project specification.

What Sizes of Y-Bar Does WFSA Supply?

WFSA supply range: Available from WFSA — request a quotation. Contact WFSA for current branch availability, lead time and the exact combination required. A listed range does not mean every branch holds every item at all times.

Current online products: Shop links identify published online listings. The online shop shows only part of the WFSA supply and manufacturing range; additional range items can be ordered by quotation.

Nominal diameterWFSA supply lengthsTheoretical mass per metre
5.6 mm6, 12 and 13 m0.194 kg/m
8 mm6, 12 and 13 m0.395 kg/m
10 mm6, 12 and 13 m0.617 kg/m
12 mm6, 12 and 13 m0.889 kg/m
16 mm6, 12 and 13 m1.580 kg/m
20 mm6, 12 and 13 m2.469 kg/m
25 mm6, 12 and 13 m3.858 kg/m
32 mm6, 12 and 13 m6.321 kg/m

Theoretical mass uses d² ÷ 162 with diameter d in millimetres. It is an estimate, not a measured or guaranteed mass; verify manufacturing tolerances and actual load mass where required. Project-required steel grade and documentation must be confirmed.

How Do You Calculate the Weight of Y-Bar?

Theoretical mass per metre ≈ d² / 162 kg/m, where d is the nominal diameter in millimetres. Multiply by bar length in metres and then by the number of bars.

The density calculation is π/4 × (d/1000)² × 7,850 kg/m³, approximately 0.006165 × d² kg/m. Dividing by 162 is a convenient rounded estimator.

Calculated theoretical mass is not guaranteed actual supplied mass. Manufacturing tolerances and the specified nominal mass basis may produce small differences. No tolerance percentage is invented in this guide.

How Much Does 10 mm Y-Bar Weigh?

10 mm reinforcing bar has a theoretical mass of approximately 0.617 kg per metre, or 3.704 kg per 6 m bar, using d²/162.

WFSA lists 10 mm × 6 m Y-bar. Use the approved bar schedule for lengths and quantities.

How Much Does 12 mm Y-Bar Weigh?

12 mm reinforcing bar has a theoretical mass of approximately 0.889 kg per metre, or 5.333 kg per 6 m bar, using d²/162.

WFSA lists 12 mm × 6 m Y-bar. Use the approved bar schedule for lengths and quantities.

How Much Does 16 mm Y-Bar Weigh?

16 mm reinforcing bar has a theoretical mass of approximately 1.580 kg per metre, or 9.481 kg per 6 m bar, using d²/162.

WFSA lists 16 mm × 6 m Y-bar. Use the approved bar schedule for lengths and quantities.

How Do You Read a Y-Bar Specification?

For exampleY-Bar / 12MM / 6M describes the product type, 12 mm nominal diameter and 6 m listed length. It does not state a steel grade, yield strength or certification.

Read these alongside the engineer’s bar mark, bending shape, cut length, quantity, position and required material standard. Keep bundle identification and delivery documents so different diameters and grades are not mixed during fabrication or installation.

The full WFSA supply range includes eight diameters from 5.6 to 32 mm, with 6, 12 and 13 m supply lengths. Read diameter and length separately.

What Is the Difference Between Reinforcing Mesh and Y-Bar?

FeatureReinforcing meshY-bar
FormWelded grid sheetsIndividual deformed bars
DistributionDistributed gridBars positioned according to design
InstallationSheets supported and tied in placeBars tied into grids or cages
Typical design roleDistributed reinforcementMain or local reinforcement as specified
CuttingMesh cutter or appropriate equipmentRebar cutter or suitable saw
Design requirementFollow approved specificationFollow approved specification

Many structures use both. Neither is a universal substitute for the other; altering the form or arrangement requires design approval.

Where Reinforcing Mesh Is Used

Welded fabric can provide distributed reinforcement in designed floor slabs, paths, paving, driveways, precast elements, walls and selected foundations. Its required reference, steel area, position and number of layers depend on the element.

Application labels in sales guides help start a discussion; they cannot select a safe reinforcement arrangement without the loads, geometry, ground/support conditions, concrete and design.

Where Y-Bar Is Used

Y-bar is used where individual reinforcing bars are specified, including beams, walls, columns, foundations, footings and slabs. Bars may form cages, grids, stirrups or other designed arrangements.

The structural drawing controls diameter, quantity, bar shape, positioning, spacing, development and laps. Do not choose these from product availability alone or substitute a smaller bar because it is easier to handle.

WFSA Reinforcing Mesh Range

WFSA supply range: Available from WFSA — request a quotation. Contact WFSA for current branch availability, lead time and the exact combination required. A listed range does not mean every branch holds every item at all times.

Current online products: Shop links identify published online listings. The online shop shows only part of the WFSA supply and manufacturing range; additional range items can be ordered by quotation.

ReferenceRange labelListed wire diameterSheet size
REF078Econo—2.4 × 6 m
REF193Econo<4.8 mm2.4 × 6 m
REF193Industry specification5.0 mm2.4 × 6 m
REF245Econo6.0 mm2.4 × 6 m
REF395Econo7.0 mm2.4 × 6 m
REF617Econo9.5 mm2.4 × 6 m
REF888Econo11 mm2.4 × 6 m
REF100SABS-labelled / specified range4.0 mm2.4 × 6 m
REF156SABS-labelled / specified range3.55 mm2.4 × 6 m
REF193SABS-labelled / specified range5.6 mm2.4 × 6 m
REF200SABS-labelled / specified range4.0 mm2.4 × 6 m
REF245SABS-labelled / specified range6.3 mm2.4 × 6 m
REF308SABS-labelled / specified range6.9 mm2.4 × 6 m
REF311SABS-labelled / specified range7.1 mm2.4 × 6 m
REF341SABS-labelled / specified range6.3 / 5.6 mm2.4 × 6 m
REF395SABS-labelled / specified range8.0 mm2.4 × 6 m
REF500SABS-labelled / specified range9.0 mm2.4 × 6 m
REF617SABS-labelled / specified range10 mm2.4 × 6 m
REF888SABS-labelled / specified range12 mm2.4 × 6 m

Range and coating labels describe the listed product.

REF341 lists 6.3 / 5.6 mm wires. Reference numbers identify fabrics; they are not wire diameters or permission to substitute one range for another.

What Reinforcement Is Used in a Concrete Slab?

There is no single mesh or bar arrangement for every slab. Requirements depend on thickness, span, support conditions, ground, loads, concrete strength, crack-control requirements and structural design.

Mesh is common in many slab applications, but floor area alone cannot select a REF type. Obtain the reinforcement schedule before buying. The calculators below estimate quantities and mass after product selection; they do not design the slab.

What Reinforcing Mesh Should Be Used for a Driveway?

Use the driveway’s approved specification. Vehicle loads, subgrade, slab thickness, joint layout, concrete strength and design all affect the reinforcement required.

A passenger-vehicle driveway and a heavy-truck yard are not equivalent. This guide does not prescribe REF100 or REF193 universally, nor convert a sales-positioning example into a structural recommendation.

Is Reinforcing Mesh Used in Foundations?

Some foundations use individual Y-bars, reinforcing cages, mesh or combinations. The approved structural drawing determines the arrangement.

Ground conditions, foundation geometry and loads matter. Do not select foundation reinforcement by choosing whatever mesh was used for a nearby floor slab. Coordinate service penetrations, cover, chairs and anchorage with the design.

Reinforcement in Footings

Footings transfer loads into supporting ground. Their reinforcement may use specified bars, cages, mesh or a combination, with exact positioning and anchorage shown on the drawings.

Keep steel supported at the specified cover and obtain approval for changes arising from ground conditions or obstructions.

Reinforcement in Walls and Beams

Walls and beams may require longitudinal bars, distribution reinforcement and shear reinforcement. Their functions and detailing differ from a simple ground slab.

Follow the approved drawings for bar direction, spacing, hooks, anchorage, laps, cover and position. Avoid moving steel around openings or services without the responsible designer’s approval.

Why Is Reinforcement Tied?

Binding wire holds bars and mesh in their specified positions during handling, placement and pouring. Tying primarily maintains the construction layout; it does not replace the structural bond between steel and concrete.

WFSA stocks plain galvanized wire, including small-pack options. Finish sharp ends safely.

What Is Concrete Cover?

Concrete cover is the distance from the outer concrete surface to the nearest surface of the reinforcing steel. It matters for corrosion protection, fire resistance, bond and durability.

Required cover depends on exposure, element, concrete, environment and applicable design standard. No universal cover dimension is given here. Measure to the nearest steel surface, including links where applicable, and maintain it using the approved supports.

Why Must Reinforcing Mesh Be Supported?

Mesh must stay at its designed position within the concrete. Approved chairs, spacers or stools maintain position and cover during pouring.

Do not leave mesh on the ground and assume it will rise into position, or rely on pulling it up during the pour. Supports must be suitable for the reinforcement and construction loading. Check stability before concrete placement and prevent workers or equipment from displacing the mesh.

How Much Should Reinforcing Mesh Overlap?

Follow the approved reinforcement drawing or project specification. Lap requirements depend on mesh type, diameter, spacing, structural purpose, stress, position and applicable design requirements.

A universal rule such as one square, 300 mm or 400 mm is not supplied here. Resolve unclear lap details before ordering or cutting; laps change installed coverage and may affect the number of sheets. Ties secure positioning but do not independently establish an adequate lap.

How Is Reinforcing Mesh Cut?

Use an appropriate commercial mesh cutter or cutting equipment suitable for the actual wire. Secure and support the sheet, plan cuts from the drawing and control movement as wires are cut.

Use gloves, eye protection and the required workplace PPE. Manage sharp wire ends, loose offcuts and manual-handling risks. Keep others clear and preserve the planned lap/anchorage lengths. Do not use unsafe improvised cutting methods.

How Is Y-Bar Cut?

Use a suitable rebar cutter, appropriate abrasive cutting equipment or a suitable saw following its operating procedure. Check bar marks, cut lengths and bending requirements before cutting.

Secure the bar, use the required PPE and manage sparks, sharp ends and nearby combustible material. Do not alter specified bends, welds or heat treatment without approval. Keep cut bars identified by size and bar mark.

How Should Reinforcing Steel Be Handled and Stored?

Store on stable, level supports away from excessive mud and standing water. Organise by type and diameter, retain identification, prevent unsafe rolling or collapsing stacks, and provide safe access for lifting.

Use suitable mechanical handling for sheets and bundles, with trained operators and approved lifting arrangements. Do not mix bar sizes. Reinforcement need not always remain completely dry, but contamination, corrosion condition and any storage damage must meet the project specification.

Light Surface Oxidation and Damaging Corrosion

Reinforcing mesh, Y-bar and certain Brickforce products are supplied as raw or black steel without a protective zinc coating. When raw steel is exposed to humidity, rain, condensation, water or wet storage conditions, a light orange-brown layer of surface oxidation can develop quickly. Light surface rust is normal on uncoated reinforcing steel and does not by itself mean that the material is defective or unsuitable for use. Heavy flaky or scaly corrosion, deep pitting, or significant loss of steel section, mass or dimension is different and should be assessed against the applicable product and project specification.

Y-bar surface condition

Y-bar is normally supplied as raw reinforcing steel. Light surface oxidation may develop during normal storage and handling, particularly after exposure to moisture. Bright, rust-free steel should not be presented as a requirement unless the applicable project specification specifically requires a particular surface condition.

REF / reinforcing mesh surface condition

Uncoated reinforcing mesh can develop orange surface oxidation rapidly after exposure to rain, condensation or humidity. Light surface oxidation must be distinguished from deep or flaky corrosion that materially affects the steel.

Oil, paint, mud and other contamination affecting bond must meet the project specification. Refer heavy corrosion, section loss or uncertainty to the responsible engineer. Cleaning must not damage ribs or reduce the steel below the required condition.

This guidance applies to raw / black / uncoated reinforcement. Galvanized Brickforce, galvanized steel and coated reinforcement have separate protective-coating specifications and must be assessed accordingly. Surface oxidation does not establish steel grade, compliance or structural suitability; the applicable project specification and responsible engineer determine acceptance where required.

How Many Reinforcing Mesh Sheets Do I Need?

Initial sheet count = ceiling(project area ÷ gross sheet area). Area = length × width; the confirmed 6 m × 2.4 m WFSA sheet has 14.4 m² gross area.

For a 10 m × 8 m rectangle, 80 ÷ 14.4 = 5.56, rounded up to 6 full sheets before laps. A selected 10% material allowance gives ceiling(80 × 1.10 ÷ 14.4) = 7 sheets. This is not a cutting layout or final schedule.

Required laps, sheet orientation, irregular geometry, openings, cutting, waste and structural detailing can change the actual quantity. A waste percentage does not automatically provide the required laps.

Reinforcing Mesh Sheet Calculator

This calculator provides a material-estimating starting point only. Reinforcement laps, cutting layout and structural requirements must be taken from the approved project specification. WFSA REF sheets use confirmed 6 m × 2.4 m gross dimensions.

How Do I Calculate Y-Bar Quantities?

Read the approved bar schedule: multiply the required number of bars by their specified cut lengths to estimate total linear metres. Convert metres to theoretical mass using the diameter-specific kg/m.

For example, ten specified 12 mm bars at 6 m each total 60 m. Their theoretical estimator mass is 60 × 12²/162 = 53.333 kg. This does not establish the required number, spacing or cut length. Cutting yield, bends, anchorage and laps must follow the schedule; total metres divided by 6 m alone may understate stock lengths if offcuts cannot be used.

Y-Bar Weight Calculator

Calculated theoretical mass. Actual supplied mass may vary within manufacturing tolerances. WFSA supply lengths are 6, 12 and 13 m; entering another cut length estimates mass and does not establish a stocked length. This tool does not determine reinforcement spacing or structural requirements.

Common Reinforcing Steel Mistakes

  • Buying by product name without checking actual specification
  • Confusing REF designation with wire diameter
  • Substituting Econo mesh for specified compliant mesh without approval
  • Using incorrect bar diameter or spacing
  • Leaving mesh directly on the ground
  • Using incorrect concrete cover
  • Providing insufficient or unstable chairs
  • Using unapproved laps
  • Moving mesh during concrete placement
  • Cutting bars before checking the drawings
  • Mixing different bar sizes
  • Unsafe stacks or poor handling
  • Allowing heavy contamination
  • Ignoring the engineer’s drawings
  • Selecting structural reinforcement from slab area alone

Check the complete reinforcement arrangement before pouring. Resolve discrepancies while they can still be corrected; a later product invoice cannot prove steel was installed in its designed position.

How to Read WFSA Reinforcing Product Descriptions

Actual shop nameMeaningSpecification
Welded steel reinforcing mesh — REF 078; 0.78 kg/m² nominal mass; economy range.REF078 economy range0.78 kg/m² nominal mass; 2.4 × 6 m sheet
Welded steel reinforcing mesh — REF 193; <4.8 mm wire diameter; economy range.REF193 economy range<4.8 mm wire; 2.4 × 6 m sheet
Welded steel reinforcing mesh — REF 193; 5.6 mm wire diameter; SABS range designation; confirm required certification.REF193 SABS-labelled 5.6 mm range
Deformed steel reinforcing bar (Y-bar) — 12 mm nominal diameter; 6 m length.Y-bar, 12 mm nominal diameter, 6 m lengthGrade and required standard are not stated in this name
Brickforce / HD / 150mm / 15mHD-labelled Brickforce, 150 mm width and 15 m listed lengthConfirm suitability for the masonry specification

Keep the distinction between quotation shorthand and the full technical specification. Use the product code and full material specification when ordering.

Reinforcing Steel FAQs

What is reinforcing mesh?

Welded steel-wire grid sheets used for distributed reinforcement within concrete.

What does REF mean?

It identifies a reinforcing fabric specification. The number is not a wire diameter; consult the schedule for wires, spacing and steel area.

What is REF100?

A fabric reference. WFSA lists REF078 Econo at 0.78 kg/m² in 2.4 × 6 m sheets, distinct from standard REF100 with 4.0 mm wire.

What is REF193?

A fabric reference. WFSA supplies Econo <4.8 mm and SABS-labelled 5.6 mm variants in 2.4 × 6 m sheets.

What is ECO reinforcing mesh?

WFSA’s economy range. Its actual specification must be checked; the ECO name does not establish standards compliance.

What is SABS reinforcing mesh?

A term used in WFSA’s REF193 product label. Confirm the relevant standard and documentation rather than treating the label alone as a certificate.

What size is a reinforcing mesh sheet?

WFSA confirms its REF reinforcing sheets as 2.4 m × 6 m, giving 14.4 m² gross area before laps.

How much does reinforcing mesh weigh?

The shop lists 11.232 kg for REF078 Econo, 18 kg for REF193 Econo and 27.792 kg for REF193 SABS-labelled.

How do I calculate reinforcing mesh sheets?

Divide project area by gross sheet area and round up for an initial count. Allow for approved laps, cutting layout, waste and detailing before final ordering.

What mesh should I use for a concrete slab?

Use the approved structural specification; area alone cannot determine the required mesh.

What is Y-bar?

A deformed reinforcing steel bar used in concrete.

What sizes of Y-bar are available?

WFSA supplies 5.6, 8, 10, 12, 16, 20, 25 and 32 mm Y-bar in 6, 12 and 13 m lengths. Request a quotation and confirm current branch availability.

How do you calculate rebar weight?

Multiply theoretical kg/m by bar length and quantity, using the nominal diameter.

How much should reinforcing mesh overlap?

Follow the approved drawing or project specification; no universal lap dimension is given.

Can rusty reinforcing steel be used?

Light surface oxidation alone does not automatically make raw reinforcing steel defective or unacceptable. Uncoated reinforcing mesh can develop orange surface oxidation rapidly after exposure to rain, condensation or humidity. Light surface oxidation must be distinguished from deep or flaky corrosion that materially affects the steel. Heavy scaling, deep pitting or significant loss of section, mass or dimension needs assessment against the applicable specification by the responsible engineer. Coated reinforcement has separate coating requirements.

WFSA Reinforcing Products

Listed rangeWire diameterSheet sizeShop-listed massProduct
REF078 Econo—2.4 × 6 m11.232 kgView product ↗
REF193 Econo<4.8 mm2.4 × 6 m18 kgView product ↗
REF193 SABS-labelled5.6 mm2.4 × 6 m27.792 kgView product ↗
DiameterListed lengthTheoretical kg/mTheoretical 6 m massProduct
5.6 mm6 m0.1941.161 kgView 5.6 mm Y-bar ↗
8 mm6 m0.3952.370 kgView 8 mm Y-bar ↗
10 mm6 m0.6173.704 kgView 10 mm Y-bar ↗
12 mm6 m0.8895.333 kgView 12 mm Y-bar ↗
16 mm6 m1.5809.481 kgView 16 mm Y-bar ↗

Related listed materials include HD Brickforce 75 mm × 15 m and HD Brickforce 150 mm × 15 m. Brickforce is a masonry reinforcement product and is not treated here as a substitute for slab mesh or designed Y-bar.

Explore plain galvanized wire and related steel products, confirming suitability for the intended role. For fencing mesh rather than concrete reinforcement, use our Welded Mesh Fencing Guide. Prices in the online store apply to Centurion only; confirm branch pricing and stock.

Need Reinforcing Steel?

Wholesale Fencing SA supplies reinforcing mesh and Y-bar for construction, trade and general concrete applications. Send the approved product specification, sheet/bar quantities, bar schedule, required standard or documentation and delivery location.

Ask about availability and handling before ordering full sheets or bundles. WFSA product assistance and material estimation do not replace the responsible designer’s structural specification.

Shop reinforcing ↗Shop Y-bar ↗Request a quote ↗Contact WFSA ↗

REF Mesh: General Application Guide

Light paths / screeds

REF100 / REF156

General reference example; confirm the specified fabric and range.

Residential floors / patios

REF193

General reference example; confirm the specified fabric and range.

Driveways / garages

REF245 / REF311

General reference example; confirm the specified fabric and range.

Workshops / commercial floors

REF311 / REF395

General reference example; confirm the specified fabric and range.

Heavy industrial floors / truck yards

REF500 / REF617

General reference example; confirm the specified fabric and range.

Higher-load structural work

REF617 / REF888

General reference example; confirm the specified fabric and range.

Application references do not establish equivalence between Econo, Industry and SABS-labelled fabric. Use the full material specification in the approved design.

WFSA Specimesh Sheets

WFSA supply range: Available from WFSA — request a quotation. Contact WFSA for current branch availability, lead time and the exact combination required. A listed range does not mean every branch holds every item at all times.

Current online products: Shop links identify published online listings. The online shop shows only part of the WFSA supply and manufacturing range; additional range items can be ordered by quotation.

ApertureFinishListed wire diametersSheet size
50 × 25 mmBlack / uncoated3.15, 4.00, 5.00 mm2.4 × 1.2 m
50 × 50 mmBlack / uncoated3.15, 4.00, 5.00 mm2.4 × 1.2 m
100 × 50 mmBlack / uncoated3.15, 4.00, 5.00 mm2.4 × 1.2 m
100 × 100 mmBlack / uncoated3.15, 4.00, 5.00 mm2.4 × 1.2 m
100 × 20 mmBlack / uncoated3.15, 4.00 mm2.4 × 1.2 m
100 × 25 mmBlack / uncoated3.15, 4.00 mm2.4 × 1.2 m
50 × 25 mmGalvanized3.15, 4.00, 5.00 mm2.4 × 1.2 m
50 × 50 mmGalvanized3.15, 4.00, 5.00 mm2.4 × 1.2 m
100 × 50 mmGalvanized3.15, 4.00, 5.00 mm2.4 × 1.2 m
100 × 100 mmGalvanized3.15, 4.00, 5.00 mm2.4 × 1.2 m

Specimesh is a separately specified welded sheet product. Reinforcing fabric, Specimesh and fencing welded mesh have different intended specifications; do not substitute them solely because they are welded grids.

Related Technical Guides

Technical Information by Wholesale Fencing SA

Wholesale Fencing SA supplies reinforcing mesh, reinforcing bar and related steel products for building, construction, trade and general concrete applications.

This guide provides general product and material information. Structural reinforcement must be selected and installed according to the approved project design, applicable standards and responsible engineer’s specification where required.

Last reviewed: October 2026