WFSA technical guides · Wire & mesh

Diamond Mesh Fencing Guide South Africa

Understand chain-link mesh, tension and the supporting system.

Diamond mesh is woven steel wire with continuous diamond-shaped openings. Commonly called chain-link fencing, it is more flexible than welded mesh and can be tensioned between structural posts.

This guide covers real WFSA product sizes, selection, posts, stays, Y/K standards, foundations, straining wires, binding, slopes and maintenance for boundaries and enclosures.

WFSA product tiers: Mzansi / Econo and specified ranges

The WFSA Mzansi / Econo range is a commercial-value range for selected price-sensitive, general-purpose, retail, hardware-store and lower-load applications where a project-specific certified or warranted specification is not required. Select it for the intended use; it is not an automatic substitute for heavier-duty, fully specified or standards-compliant material.

Depending on the product, differences can include actual wire diameter, coating level, mass, steel content and manufacturing tolerance. Compare the individual specifications rather than height, mesh opening or purchase price alone.

Product tierPurposeWhat to check
Mzansi / EconoSelected price-sensitive and general-purpose applicationsActual diameter, coating, mass, intended use and warranty status
Standard WFSA rangeGeneral agricultural and commercial use appropriate to the productThe stated individual product specification
Specified / Heavy / Compliant rangeProjects requiring a defined technical specificationExact diameter, tensile properties, coating, standard and certification required; a range label alone is not certification

Unless specifically stated otherwise, economy / VL / LD products are not supplied with a general warranty on service life or long-term performance. This does not exclude statutory consumer rights where applicable. Read the WFSA terms and conditions and Do not use economy material as a substitute for a required structural or certified specification.

What Is Diamond Mesh?

Diamond mesh, commonly called chain-link fencing, consists of wire woven into a continuous diamond-shaped pattern. Wire strands interlock rather than being welded at crossing points.

The woven structure makes the material comparatively flexible and allows it to be tensioned between structural posts. Flexibility does not remove the need for properly braced strain sections and secure support wires.

How Is Chain-Link Mesh Made?

Formed wire strands are woven/interlocked to create the diamond pattern. The roll is supplied to a specified aperture, wire diameter, height, length and coating.

Inspect the roll for damaged wire, distorted openings and coating damage before installation. Do not infer tensile properties or coating mass from appearance.

Diamond Mesh Sizes

Current WFSA woven galvanized diamond-mesh listings use the combinations below. All these examples are 30 m rolls; not every diameter/aperture combination is listed in every height.

HeightApertureListed wire diameterExample
1.2 m50 mm2.00 mmView a listed example
1.2 m75 mm2.00 / 2.50 mmView a listed example
1.8 m50 mm2.00 / 2.20 mmView a listed example
1.8 m75 mm1.70 / 2.00 / 2.25 / 2.50 mmView a listed example

A separate razor diamond-mesh product in the category is a different security material, not an ordinary woven chain-link roll. Do not apply the table’s dimensions or installation assumptions to it. Browse current diamond mesh and

How Do I Choose Diamond Mesh?

Specify wire diameter, aperture, height, roll length, galvanizing and application. A smaller opening affects containment and access; a larger steel diameter can increase strength, but neither alone defines the complete fence.

Assess loads, animal behaviour or security risk, supports, terrain, bottom gaps, gate openings and environmental exposure. Steel diameter and zinc-coating mass must be considered separately. A flexible mesh still needs compatible structural posts and terminations.

Diamond Mesh Applications

Diamond mesh is used for property boundaries, residential fences, animal enclosures, agricultural and industrial fencing, specified security barriers, sports facilities and general-purpose enclosures.

Confirm suitability for the actual duty. Animal pressure, digging, entrapment and climbing can require a different aperture or ground detail. Sports or industrial applications may have their own project requirements. The Farm Fencing Guide provides further livestock selection advice.

Diamond Mesh vs Welded Mesh

FeatureWelded meshDiamond mesh
ConstructionWelded intersectionsWoven/interlocked wire
ApertureSquare or rectangularDiamond-shaped
RigidityComparatively more rigidComparatively more flexible
TerrainLess conformableGenerally more adaptable
InstallationSupported and tied, with controlled positioning/tensionTensioned, supported and tied
UsesGeneral fencing, agricultural and equipment/animal enclosures; specified security systemsBoundaries, enclosures, agricultural and specified security applications

Neither product is universally better. Choose the complete fence for the application, ground conditions, loads, aperture, height and protective coating.

Read the Welded Mesh Fencing Guide and compare listed welded mesh.

Galvanizing and Coastal Diamond Mesh

For the complete explanation of zinc, alloy and outer coating systems, read the WFSA Corrosion, Galvanizing & Protective Coatings Guide.

Standard and heavy galvanising describe different levels of zinc protection; the word “galvanized” alone does not establish coating mass or service life. Thicker steel wire is not automatically more heavily galvanized.

Choose coating for the atmosphere, moisture, intended life and maintenance. WFSA Standard galvanised wire uses Class C and Heavy galvanised wire uses Class A. Coating class describes zinc protection separately from wire strength.

For coastal or aggressive exposure, WFSA recommends heavy galvanised wire or another appropriately specified enhanced-corrosion-resistant system. Include mesh, binding wire, straining wire, posts, standards, stays, fixings and gates. Read the Galvanized Fencing Wire Guide for more detail.

Diamond Mesh Fence Posts

Select the major posts, stays and intermediate supports as one structural arrangement. Mesh height and weight, wire tension, wind exposure, soil and gate loads all affect the required capacity. A light shop post is not automatically suitable as a major straining post.

Browse WFSA posts and stays. The store includes painted and light-duty options; Listed examples are descriptions of products, not an engineered approval.

How Far Apart Should Straining Posts Be?

WFSA generally recommends major straining posts at maximum intervals of approximately 30 metres and at every corner, end, gate or significant change in fence direction. These posts resist the horizontal loads of the strain section; intermediate standards do not replace them.

Can straining posts be more than 30 metres apart?

Only where the post, stays and foundation system have sufficient structural capacity for the increased strain length. A heavier-duty example to consider is an approximately 101 mm outside-diameter circular steel post with minimum 3 mm wall thickness. This example does not automatically permit any particular wider spacing.

Assess fence height, total strain length, mesh weight, wire tension, soil, wind, foundation, stays and gate loads. Obtain a site-specific design where wider spacing is required rather than extrapolating from the example.

How Many Stays Are Required?

WFSA generally installs two stays at each major straining or corner post. Stays resist horizontal fence loads; at corners they must support the relevant fence directions.

A general stay foundation is approximately 400 × 400 × 600 mm deep in concrete. This is installation guidance, not a universal structural specification. Confirm stay angle, connections, post capacity and foundation requirements for the soil and load; two inadequately connected stays do not provide a reliable anchor.

Choose compatible posts and stays with an appropriate protective finish.

Y and K Standards

WFSA generally places intermediate Y or K standards at approximately 3 metre centres. They support the mesh and horizontal straining wires, maintain line and height, and reduce movement between major posts.

Listed 1.8 m Y standards2.4 m Y standards and 3.0 m Y standards can be compared with 1.8 m K standards and 2.4 m K standards. Select length, embedment and coating for the installed fence height and ground conditions; standard length is not finished fence height.

Does this mesh fence need droppers?

Not normally in this WFSA installation configuration. The mesh supplies continuous vertical structure and is supported by Y/K standards. This does not override an approved project detail requiring additional supports.

Horizontal Straining Wires

WFSA generally installs horizontal straining wires at approximately 600 mm vertical intervals measured upward from the bottom of the fence. The number of lines depends on fence height; there is no fixed line count suitable for every height.

Specify the bottom and top support arrangements and the position of intermediate lines for the actual mesh. Support wires must be securely terminated to the major post system and tensioned without moving posts or foundations.

WFSA lists 2.24 mm Heavy galvanised (Class A) high-strain wire, 1,650 m and a range of plain galvanized wire. Read the Galvanized Fencing Wire Guide for complete-system corrosion protection.

How Often Should Diamond Mesh Be Tied?

WFSA generally binds mesh to horizontal straining wire at approximately 100 mm intervals. Frequent secure ties hold the mesh against its supporting wire, maintain alignment, reduce movement and loose sections, and produce a neat installation.

Binding wire is the wire used to secure the mesh to its supports; it does not replace a structural straining wire. Select a diameter and corrosion protection compatible with the mesh and approved installation. Avoid cutting or damaging the main wire with an excessively tight tie, and finish wire ends so they do not create exposed sharp projections.

The galvanized wire range includes a 2.50 mm / 1,300 m listing. This is a real product example, not a requirement to use that diameter for every fence.

How Deep Should Diamond Mesh Fence Posts Be?

WFSA’s general recommendation for major straining and corner posts is a concrete foundation approximately 400 mm × 400 mm × 600 mm deep. This is a general installation recommendationnot a universal structural-engineering specification.

Actual foundation dimensions and post embedment depend on soil, fence height, mesh, wind, post size, gate loads, terrain, security requirements and site conditions. Foundation depth and effective steel embedment are related but are not automatically identical; follow the approved detail.

Finish the top of the concrete with a raised/sloped surface so water drains away from the steel post. Do not leave a depression that retains water around the steel. Allow adequate foundation stability before tensioning the fence or loading gates; concrete requirements and curing/loading times must follow the project specification.

Posts in Sandy or Weak Soil

Very sandy, loose or weak soil gives less lateral support to a loaded post. WFSA recommends increasing major-post embedment beyond the normal installation depth where these conditions occur.

Depending on the site, major posts may need to be planted to approximately 1 metre deep. This is a consideration for weak ground, not a guaranteed design solution or a fixed depth for all sandy soils.

Possible measures include deeper installation, a larger foundation, a heavier post and improved bracing. Assess the actual soil and loads together, including stays and gate supports. Investigate unsuitable ground before tensioning rather than relying on extra depth alone.

WFSA Diamond Mesh Installation System

WFSA’s general structural arrangement uses major straining posts, two stays at each major post, intermediate Y/K standards, horizontal straining wires, binding wire and woven diamond mesh. Major posts anchor tension; intermediate standards maintain support and alignment.

All approximate dimensions in this guide are general recommendations. Soil, height, wind, strain length, gate loads and security requirements can require a revised design.

How Is Diamond Mesh Tensioned?

Tension diamond mesh evenly along the fence line to produce a firm, uniform fence without excessive distortion of the diamond apertures. Work only after foundations and stays have adequate stability and use an appropriate controlled installation method.

Spread the load across the mesh height rather than pulling isolated strands. Check the run as tension is applied: stop if posts move, foundations shift, standards lean, openings distort or wire is damaged. Correct the support or setup before continuing.

More tension is not a substitute for a properly braced post system. The required tension depends on the mesh and approved detail; no universal force or tool setting is specified here.

How Do You Install Diamond Mesh Fencing?

  1. Survey and mark the fence line

    Confirm the boundary, ground profile and buried services before excavation. Establish a reference line and identify obstructions.

  2. Locate corners and gates

    Mark ends, changes of direction and openings. Agree gate clearances and support details before calculating mesh runs.

  3. Set out major posts

    Use maximum intervals of approximately 30 m in the general WFSA arrangement, plus major posts at corners, ends and gates. Shorten sections where the terrain or loads require it.

  4. Excavate major foundations

    Check soil and excavate to the approved detail. The general example is 400 × 400 × 600 mm deep; revise the design for weak or sandy ground.

  5. Install major posts

    Position and support the straining/corner posts in the specified concrete foundations. Check verticality and finish the top to drain away from steel.

  6. Fit two stays

    Connect two stays to each major post in the directions needed to resist the fence loads. Use appropriate connections and sections.

  7. Concrete the stays

    The general stay-foundation example is 400 × 400 × 600 mm deep. Confirm the soil/load detail and allow adequate foundation stability.

  8. Install intermediate standards

    Place Y or K standards at approximately 3 m centres. Check embedment, alignment and installed support height.

  9. Fit straining wires

    Arrange horizontal lines at approximately 600 mm vertical intervals upward from the bottom. Set line count and terminations for the fence height.

  10. Unroll the mesh

    Handle the roll safely along the prepared line. Avoid snagging, dragging on sharp surfaces or damaging the coating.

  11. Position the mesh

    Set the planned height and ground clearance. Align joins and prepare proper corner/end terminations.

  12. Apply controlled tension

    Tension evenly until the mesh is firm and uniform without pulling posts, leaning standards or distorting diamond openings.

  13. Bind to support wires

    Tie mesh to horizontal straining wires at approximately 100 mm intervals with suitable binding wire and neatly finished ends.

  14. Secure at standards

    Retain mesh and support wires to Y/K standards with the specified ties and connections. Check for loose areas.

  15. Complete corners and gates

    Use the planned major-post terminations and gate support details. Do not transfer a corner load onto an ordinary intermediate standard.

  16. Check line and level

    Inspect alignment, height, ground clearance, standards, posts and stays along the run. Resolve foundation movement before further tensioning.

  17. Inspect protective finishes

    Check damaged coating, cut ends and connections. Repair or replace using a compatible approved method.

  18. Clean and hand over

    Remove wire offcuts, sharp debris and temporary equipment. Inspect gate operation and record maintenance or outstanding specification requirements.

Installing Corners

Place a major straining/corner post at a change of direction and brace it for the relevant fence runs. Two stays are the general WFSA arrangement, with connections and foundations selected for the actual loads.

Terminate and restart strain sections using the specified connection. Do not drag mesh around an unsupported corner or use an intermediate standard as the load-bearing anchor. Check line, tension and bottom clearance on both sides of the corner and maintain corrosion protection at connections.

Installing Gates

Locate gate openings before setting out strain sections. Gate posts and foundations must support the gate’s weight and operating loads in addition to fence tension; an ordinary intermediate support is not automatically a suitable hinge post.

Terminate mesh securely at the gate posts, maintain the intended ground gap and check hinges, latches, opening direction and clearance. Do not load or operate a gate before its foundation is adequately stable.

Explore diamond mesh gates or farm gates, and request a quotation for an opening or finish that requires a specific arrangement.

Can Diamond Mesh Be Installed on a Slope?

Yes. Woven diamond mesh generally provides more flexibility than rigid welded mesh, but it still needs correct post positioning, mesh tension, ground clearance, termination and straining.

Survey the profile and divide the line into suitable strain sections. Position the roll to maintain the planned bottom gap and installed height, without forcing diamonds out of shape. Abrupt slopes, drainage crossings or major terrain changes may need additional straining points or a specific detail.

Check the mesh at ground changes and gate approaches. Do not leave an escape gap or force a gate support to absorb an incorrectly planned slope.

Common Diamond Mesh Installation Mistakes

  • Major posts too far apart without a designed capacity increase
  • Posts too light for the mesh, tension or gates
  • Poor concrete foundations or inadequate embedment in sandy soil
  • Missing stays, or one stay where the specified two are required
  • Y/K standards too far apart
  • Missing straining wires or incorrect vertical spacing
  • Too few binding ties or loose sections
  • Over-tensioning and distorted apertures
  • Weak corners and inadequate gate posts
  • Concrete retaining water around steel posts
  • Unsuitable galvanizing for aggressive exposure
  • Loading foundations before adequate stability

Inspect the complete system rather than attempting to compensate for weak supports with more tension.

Diamond Mesh Fence Maintenance

Inspect the fence periodically and after storms, impacts, ground movement or fire. Check mesh damage, broken welds or distorted woven wire as relevant, loose ties, straining-wire tension, leaning standards, post movement, foundations, stays, gates and coating damage.

Keep excessive wet vegetation and debris away from lower wires, maintain drainage around posts and repair coatings with a compatible method. Investigate a loose fence before re-tensioning: weak foundations or failed stays need correcting first. Replace damaged materials where re-tensioning cannot restore safe performance.

Diamond Mesh Fencing FAQs

What is diamond mesh?

A continuous woven/interlocked steel-wire mesh with diamond-shaped openings. Its intersections are not welded.

What diamond mesh sizes does WFSA sell?

Current woven-mesh listings include 1.2 m and 1.8 m heights in 30 m rolls, with 50 mm or 75 mm apertures and listed wire diameters from 1.70 to 2.50 mm in specific combinations. See the size table for actual combinations.

How far apart should diamond mesh straining posts be?

WFSA generally recommends maximum intervals of approximately 30 m, plus major posts at corners, ends, gates and significant direction changes. Wider sections need adequate designed capacity.

How deep should posts be?

A general major-post foundation is approximately 400 × 400 × 600 mm deep. Actual embedment and foundation requirements depend on the soil, height, tension, wind and loads.

How many stays are required?

WFSA generally uses two stays per major straining or corner post. Their directions, connections and approximately 400 × 400 × 600 mm general foundation examples must suit actual loads.

How far apart should Y standards be?

Approximately 3 m centres in the general WFSA mesh installation configuration, subject to the approved detail.

Does diamond mesh need droppers?

Not normally in this WFSA configuration, because continuous mesh provides vertical structure between Y/K supports. Follow any project-specific additional-support requirement.

How far apart should straining wires be?

Approximately 600 mm vertically, measured upward from the bottom. The number of support lines depends on height and the specified top/bottom arrangement.

How often should diamond mesh be tied?

Approximately every 100 mm along the horizontal straining wires, using suitable binding wire in the general WFSA arrangement.

How is diamond mesh tensioned?

Evenly along the strain section until firm and uniform, without distorting diamonds, pulling posts, moving foundations, leaning standards or damaging wire.

Can diamond mesh follow a slope?

Yes. Woven construction is generally more flexible than welded mesh, but post positioning, tension, bottom clearance, straining and terminations still need planning.

Can diamond mesh be used for dogs?

Yes where wire strength, aperture, height, gates and ground treatment suit the dog’s size and climbing, jumping, chewing or digging behaviour. Ordinary mesh is not a containment guarantee.

Can diamond mesh be used for security?

It can be part of a specified barrier, but ordinary chain-link mesh alone does not establish a high-security perimeter. Assess aperture, height, posts, gates, ground gaps and additional systems.

What is the difference between diamond mesh and welded mesh?

Diamond mesh is woven with flexible diamond openings; welded mesh has fixed welded square/rectangular openings and is comparatively rigid. Choose according to the application.

What diamond mesh should be used near the coast?

WFSA recommends heavy galvanised material or an appropriately specified enhanced-corrosion-resistant system for coastal/aggressive exposure. Include ties, straining wires, posts and gates.

Request a Diamond Mesh Quotation

Send WFSA the application, fence length and height, mesh aperture, wire diameter, site location, soil/terrain information, gate openings, required coating and delivery/installation scope. Include drawings where available.

Use the current listing when ordering a standard product. Online store prices apply to the Centurion branch only; contact Bloemfontein or George for their branch prices. Listed sizes do not guarantee immediate stock or a particular coating certification.

Request a Quote ↗Contact a WFSA Branch ↗

Farm Fencing Guide · Wholeview / Clear View Guide · Galvanized Fencing Wire Guide

WFSA Diamond Mesh Supply Range

WFSA supply range: Available from WFSA — request a quotation. Contact WFSA for current branch availability, lead time and the exact combination required. A listed range does not mean every branch holds every item at all times.

Current online products: Shop links identify published online listings. The online shop shows only part of the WFSA supply and manufacturing range; additional range items can be ordered by quotation.

RangeApertureWire size / range labelFinishRoll lengthListed heights
Commercial / CQ VeryLightStandard galvanised (Class C)25 m1.2 m, 1.8 m
Commercial / CQ VeryHeavyStandard galvanised (Class C)25 m1.2 m, 1.8 m
Commercial / CQ VeryVery HeavyStandard galvanised (Class C)25 m1.2 m, 1.8 m
Commercial / CQ LightStandard galvanised (Class C)25 m1.2 m, 1.8 m
Commercial / CQ HeavyStandard galvanised (Class C)25 m1.2 m, 1.8 m
Commercial / CQ Very HeavyStandard galvanised (Class C)25 m1.2 m, 1.8 m
Listed fencing range40 mm2.0mmStandard galvanised (Class C)30 m1.2 m, 1.8 m
Listed fencing range50 mmStandard galvanised (Class C)30 m1.2 m, 1.8 m
Commercial / CQ50 mm2.00mmStandard galvanised (Class C)30 m1.2 m, 1.8 m
Listed fencing range50 mm2.0mmStandard galvanised (Class C)30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 3.0 m
Listed fencing range50 mm2.20mmStandard galvanised (Class C)30 m1.2 m, 1.8 m
Listed fencing range50 mm2.50mmStandard galvanised (Class C)30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 2.7 m, 3.0 m
Listed fencing range50 mm2.50mmStandard galvanised (Class C)15 m3.6 m
Listed fencing range50 mm3.15mmStandard galvanised (Class C)15 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 2.7 m, 3.0 m
Listed fencing range64 mm1.7mmStandard galvanised (Class C)30 m1.2 m, 1.8 m
Listed fencing range64 mm1.90mmStandard galvanised (Class C)30 m1.2 m, 1.8 m
Listed fencing range64 mm2.00mmStandard galvanised (Class C)30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 2.7 m, 3.0 m
Listed fencing range64 mm2.20mmStandard galvanised (Class C)30 m1.2 m, 1.8 m
Listed fencing range64 mm2.50mmStandard galvanised (Class C)30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 2.7 m, 3.0 m, 3.6 m
Listed fencing range64 mm3.15mmStandard galvanised (Class C)15 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 2.7 m, 3.0 m
Mzansi / EconoMzansi mmStandard galvanised (Class C)30 m1.2 m, 1.8 m
Listed fencing range75 mm1.70mmStandard galvanised (Class C)30 m1.2 m, 1.5 m, 1.8 m
Commercial / CQ75 mm2.00mmStandard galvanised (Class C)30 m1.2 m, 1.8 m
Listed fencing range75 mm2.00mmStandard galvanised (Class C)30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 3.0 m
Listed fencing range75 mm2.25mmStandard galvanised (Class C)30 m1.2 m, 1.8 m
Listed fencing range75 mm2.50mmStandard galvanised (Class C)30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 2.7 m, 3.0 m, 3.6 m
Listed fencing range75 mm3.15mmStandard galvanised (Class C)15 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 3.0 m
Listed fencing range40 mm2.0mmHeavy galvanised (Class A)30 m1.2 m, 1.8 m
Listed fencing range50 mm2.00mmHeavy galvanised (Class A)30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m
Listed fencing range50 mm2.50mmHeavy galvanised (Class A)30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 2.7 m, 3.0 m
Listed fencing range50 mm2.50mmHeavy galvanised (Class A)15 m3.6 m
Listed fencing range45 mm2.50mmHeavy galvanised (Class A)15 m3.6 m
Listed fencing range50 mm3.15mmHeavy galvanised (Class A)15 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 2.7 m, 3.0 m
Listed fencing range64 mm2.00mmHeavy galvanised (Class A)30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 2.7 m, 3.0 m
Listed fencing range64 mm2.50mmHeavy galvanised (Class A)30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 2.7 m, 3.0 m, 3.6 m
Listed fencing range64 mm3.15mmHeavy galvanised (Class A)15 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 2.7 m, 3.0 m
Listed fencing range75 mmHeavy galvanised (Class A)30 m1.2 m, 1.8 m
Listed fencing range75 mm2.00mmHeavy galvanised (Class A)30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.4 m, 3.0 m
Listed fencing range75 mm2.50mmHeavy galvanised (Class A)30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 2.7 m, 3.0 m, 3.6 m
Listed fencing range75 mm3.15mmHeavy galvanised (Class A)15 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 2.7 m, 3.0 m
Listed fencing range45 mm2.00mmPVC-coated30 m0.9 m, 1.2 m, 1.8 m, 2.1 m, 2.4 m, 3.0 m
Listed fencing range mmPVC-coated30 m30 m
Listed fencing range45 mm2.00mmPVC-coated18 m3.6 m
Listed fencing range50 mm2.00mmPVC-coated30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 3.0 m
Listed fencing range64 mm2.00mmPVC-coated30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 3.0 m
Listed fencing range75 mm2.00mmPVC-coated30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 3.0 m
Listed fencing range50 mm2.50mmPVC-coated30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 3.0 m
Listed fencing range64 mm2.50mmPVC-coated30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 3.0 m
Listed fencing range75 mm2.50mmPVC-coated30 m0.9 m, 1.2 m, 1.5 m, 1.8 m, 2.1 m, 2.4 m, 3.0 m

Range and coating labels describe the listed product.

For PVC-coated wire, Economy/range names do not establish a strength or service-life guarantee.

Related Technical Guides

Technical Information by Wholesale Fencing SA

Wholesale Fencing SA supplies fencing wire, agricultural fencing, mesh and related fencing products for trade, agricultural, commercial and retail applications.

This guide provides general technical information. Installation design should suit site conditions, applicable project requirements and current standards.

Last reviewed: October 2026